test(ci): diagnose socat startup and add private Python fallback
This commit is contained in:
1 parent
5f542a6aa3
commit
7b80f411b2
24 files changed
+338
-31
No files matched your search
@@ -142,3 +142,6 @@ New source in `tests/ci/oidc_e2e/run.sh`: test namespace-local Traefik proxy Hos
|
||||
|
||||
|
||||
**P05-OIDC-02 Gitea Run #91 result:** tested `4831165`, job #198 overall FAIL. All 4 services healthy PASS, no runner host port PASS, private Traefik:80 Host-route HTTP 200 PASS, prebuilt socat/digest verification PASS. The run-owned socat sidecar **exited 1** before forwarded 8080 check, so no project/client/user or Chromium/Auth.js checks executed. Mandatory cleanup PASS, no remaining owned resources. Source-only status readiness fix in `provision.py` **was not exercised**. Root cause inside sidecar unproven without redacted startup error diagnostics. Next separately approved P05-OIDC-03 limited to private CI process/diagnostics.
|
||||
|
||||
|
||||
**P05-OIDC-03 approved CI-only source:** The existing manual workflow is unchanged. Run #91's verified socat exit 1 justifies a single-run diagnostic attempt plus a one-time deterministic, digest-pinned `python:3.12-alpine` stdlib private forwarder fallback. Only run-labeled containers, 127.0.0.1:8080 → private Traefik:80, bounded error-class diagnostics and original proxy Host HTTP 200 gate are permitted. The diagnostic/fallback happens before real provisioning; no authentication, browser or cleanup source changed. A new single Gitea run must prove all real client/user/browser/callback/session and mandatory owned cleanup checks or remain BLOCKED.
|
||||
Reference in new issue
Block a user